OpenGate System
WDS Breakdown
WDS is comprised of 3 components
Controller iPad - LiDAR, High Resolution Camera, and processing power, either mounted on the wall, hanging from the ceiling, or on a designated stand.
Operator iPad (optional) - Used by security personnel for reviewing alerts and completing IRRs, as needed. Location is based on customer needs and walk-through documentation (ref. Pre-Setup)
CEIA OpenGate system - Third-party metal detection poles. Reference WDS Installation section for CEIA specifications for placement and use.
WDS Installation
Set poles 27.5 to 36 inches apart (28-32 inches preferred), with the handles pointed in the direction of the Controller iPad.
Install batteries, and power on the OpenGate poles via the switch under the battery cover on each pole
If poles do not boot to green lights after one minute, troubleshoot or contact Support
Place the Controller iPad four to twelve feet from the OpenGate and four to ten feet from the ground, in a slightly diagonal position on the exit side of the poles
Place the Operator iPad where a Security Officer will be positioned to handle alerts
Setup Controller iPad
Open Operator App.
Align pole view to provide the highest possible accuracy percentage.
Zoom view to acquire the most landmarks as possible while still accommodating subjects of varying heights.
Setup Operator App
Open Operator App.
Ensure connection to the Controller iPad.
Test that the Operator is receiving data when a subject passes through the OpenGate.
CEIA OpenGate Details
Screening Operation
The Screener should be standing 5 - 8 feet away from the poles
If the lights on the poles remain green, the individual is clear and can proceed through the checkpoint
If the lights turn red then the individual needs to be sent for secondary screening. An auditory alarm may also be enabled.
Secondary Screening
Choose what method is best for your organization
Circular carousel method
Separate and wand
At secondary screening the individual should empty their pockets and their bags should be checked to determine the source of the alarm
Portability
Both the iPads and OpenGate are highly portable, with the poles weighing approximately 25 lbs. each
When relocating the WDS, considerations should be made concerning interference, such as moving metal and electronic noise (e.g. metal doors, wheel chairs, etc.)
(Each pole is approx. 25 lbs, +5 per battery inserted)
Detection Levels
International Security Standards per National Institute of Justice (NIJ)
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article